Floor Sensor Resistance

3 meter floor temperature sensor probe for underfloor heating thermostat features works with a wide range of different thermostats.
Floor sensor resistance. Describes the situation the problem occurs or the environment that the question applies to including products affected. To answer your question the resistance reading will be different on different floor probes the sensor and stat resistance readings must match in order for the system to operate correctly. The resistance will vary according to the temperature i e the colder the sensor the higher the resistance. Every comfortzone electric underfloor heating thermostat should be set up with a floor temperature sensor probe to monitor the temperature of your floor.
The slab sensor 079 is commonly used for floor temperature sensing in floor heating applications. Warmup heating cables are constant wattage cables that should be tested on a 200 ohm scale. This sensor is designed to provide a thermostat with the ability to maintain a minimum slab temperature or help to limit the maximum slab temperature. Every comfortzone electric underfloor heating thermostat should be set up with a floor temperature sensor probe to monitor the temperature of your floor.
Duct tape the floor sensor probe on top of the nuheat mat. To ensure that your floor heating system will function properly always test the resistance of your wires with a digital multimeter set to 200 ohms before during and after installation. If a different sensor is used it would give false readings to the thermostat and potentially cause the system to not work. Secure floor sensor probe.
The thin casing allows for retrofit installation between tile spaces if necessary. The probe s tip should be between the heating wires. Suitable for use in wet areas ip68. What is the resistance of the floor sensor circuit for the aube th232 underfloor heating thermostat.
All electrical work should be carried out by a qualified professional and adequate. 10k ntc th232 resistance sensor circuit resistance. Perform insulation and resistance test on page 6. Test the floor temperature sensors using a multimeter to verify accuracy of the sensors.
This video shows you how to test the resistance of your sensor probe correctly to identify any faults. Set the multimeter for resistance at 10k ω 2 at room temperature and take a reading between the sensor leads. Test 4 temperature sensor. Works with a wide range of different thermostatsplease check the resistance values of your current sensor against the table below for compatibility 3 metre long cable cable has high rigidity allowing it to be easily passed through existing flexible conduit suitable for use in wet areas.
Please check the resistance values of your current sensor against the table cable has high rigidity allowing it to be easily passed through existing flexible conduit.