Floor Strength 2x6 Vs Oak

Unlike syp oak is typically cut with a band saw rather than a planer.
Floor strength 2x6 vs oak. One is the maximum stress that the material can endure before failure occurs. 1500 1400 1200 950 900 800 775 725 675 425. I am not an engineer just my thoughts. Bur oak in the white oak lumber group is 10 300 psi.
Dense select structural select structural non dense select struc no. 2700 2550 2350 1750 1650 1500 1450 1250 1150 750. Acacia 17 500 psi. The greater the resistance the stronger the material.
Andiroba 15 620 psi. The species of lumber size of lumber and the load it carries. An inaccessible attic space on the other hand might have a live load of only 20 psf. Amendoim ybarro 16 900 psi.
Another approach is to measure the deformation or strain that results from a given level of stress before the point of total failure. Here is the strength of the woods in question. Angelim pedra 17 600 psi. Hi all i have a project where i want to replace some plywood with some aluminum plate.
Maximum floor joist span no. In the trailer industry oak decking is referred to as rough oak for a reason. Australian cypress 11 400 psi. Oak is one of the only decking materials recommended for use with tracked equipment such as skid steer loaders and excavators.
Edited 8 14 2005 6 42 pm et by wyatt. Aluminum 02 17 2009 07 05 pm. Likewise within the white oak grouping some are stronger than others. Ash 15 000 psi.
660 565 480. Fewer posts on upper level decks are typically more desirable to the occupants and this drives the use of larger framing materials for longer spans. Rough oak is used for trailer decking primarily for its strength. The span of a beam is dependent on a few variables.
Approx strength of wood vs. First floor live loads have higher requirements than second floor live loads 40 pounds per square foot vs. A room used solely for sleeping might need to carry only 30 psf whereas a garage floor over a basement would need 50 psf or higher. Strength in bending mor of white oak at 12 percent moisture content mc is 15 200 psi.
90 90 90 90 90 90 90 90 90 90. Note that there are several ash species and they are not all the same strength. One way that i have seen an engineer fix a cut floor truss was to gusset on both sides with 1 2 plywood. 3100 2930 2700 2010 1900 1720 1670 1440 1320 865.
To compare to other design loads residential floors are generally 40psf live and 10 psf dead decks and balconies are 60 or 100psf depending on area and 10psf dead load. By sistering up the 2 oc 2x6 with 2x6 s i would think the the strength of the floor would change to 2x6 1 oc.